User guideDoortello HomeIssue 1.00
Page 8
First activation
Install and configure the door station as you wish. Ensure that you follow the
instructions of the single modules for a correct installation. Connect the module
together following the provided cabling instructions. After this you can connect
the door phone with the telephone line and the external power supply.
- Connect FIRST the telephone line and then the external power supply.
Please note!
The external power supply voltage MUST NOT BE HIGHER THEN 12 Vrms!
Check the voltage using a voltmeter! A higher voltage may seriously damage
the device voiding you warranty! We suggest the use of our PRS 210
transformator.
Please note!
You need a separate power supply unit for each door phone you are going
to install!
- After you switch on the power supply the unit will follow an internal start up
procedure. This may take some seconds. Wait that the red LED goes off. After
this the device is ready to be used.
Automatic heating element
If the device has an automatic integrated heating element. This is used to ensure
a correct functionality with outside temperature down to - 20°C. The heating
element is activated automatically at +10°C and will be deactivated at +20°C.
Impedance 600 Ohm (default)
Impedance Zr
Jumpers for line impedance adaptation