*#4 OK tone #3 {activation code} ** {driver contact no.} OK tone
As activation code the values from 7 to 9999 can be programmed. If you
program the value 0 the driver contact will be deactivated.
As driver contact no. the value 1 (driver contact 1) and 2 (driver contact 2) can
be used.
Example:
n You want to program that the driver contact 2 should be activated using the
code "702". Input:
*#4 OK tone #3702**2 OK tone
Please note!
The device will verify if the code you are programming is not already used. If
you will get a NOOK tone after the new code input, this may be already used.
You have then to use another code. Only code starting with the digits 7, 8
and 9 can be used. If you are using codes with only one digit no other code
with more digits can be programmed using the same starting digit (i.e. you
can use "71" and "72", but not "7" and "71"). If you want to program a new
code as described in the example you have then first to delete the existing
code "7" for the driver contact 1, or modify it to another value (i.e. "701").
Maximum line seizure time
The Doortello Home speakerphone has a timer to control the maximum line
seizure time. This timer is activated a soon as the line is seized and will terminate
the connection when the programmed time is counted down. As default this
timer is set to 60 s. This can be changed or deactivated. To modify the maximum
line seizure time please follow this procedure:
*#7 OK tone *1 {max. seizure time in s} OK tone
Value between 030 and 999 can be selected. With the value 000 the
timer is deactivated.
Example:
n You want to enhance the max. seizure time to 2 minutes. Input:
*#7 OK tone *1120 OK tone
Please note!
This timer is a security feature. If the connection (i.e. using VoIP) doesn’t send
a busy tone after the called party hangs up the connection termination is